Electric Heating Installation in Dubai: Underfloor, Towel Rails, Fireplaces and Patio Heaters

Dubai needs heating for a few hours on a few weeks of the year, so the question is not whether to heat a whole house. It is where a small amount of heat is worth the wiring: a marble bathroom floor on a January morning, a towel rail that dries towels, a terrace or majlis on a cool evening, or a fireplace that is as much furniture as heater. Each of those is a separate electrical job with its own load, circuit and safety rules.

Circuit Dubai fits and wires electric heating in villas, apartments and small commercial spaces across Dubai: underfloor mats and cables, towel rails, wall and bathroom heaters, electric fireplaces, outdoor infrared heaters and electric showers. Every circuit is sized from the heater's rating, protected by a 30 mA earth leakage device, and tested before it is switched on.

What electric heating installation with us includes

A site visit or photo check of the room, the floor build-up, the board and the route for the cable.

Underfloor heating, from the mat or cable to the floor sensor, thermostat and a record drawing of where the heating is.

Towel rails and bathroom heaters, hardwired through a fused connection outside the wet area.

Fireplaces and wall heaters, with a circuit sized to the unit and the wiring hidden before the wall is closed.

Outdoor infrared heaters, on their own weatherproof circuit with the controls where you can reach them.

Testing and handover: resistance and insulation readings recorded at each stage, a trip test, and a note of the settings.

The numbers at a glance

Typical answer for a Dubai home

Heating seasonRoughly December to February, a few hours a day
Underfloor heating output150 W per m² is the usual figure for tiled floors
Running cost, 4.5 m² bathroom floorAbout AED 0.70 a day for 3 hours, around AED 60 for a whole winter
Circuit protection30 mA earth leakage device on every bathroom circuit and every heating circuit
Underfloor heating on a new floorTested at three stages, and not switched on until the tile adhesive has cured
Outdoor heater3 kW draws 13 A, so it gets its own circuit
What we need to quoteRoom sizes, floor type, photos of the board, and the make and model of any heater you have bought

Before you buy, check the heater's rating plate or the maker's manual for its wattage and voltage. Some heaters, especially UK-made showers and panel heaters, are rated for 240 V, and a 240 V element on 230 V gives about 8 per cent less heat. Send us the model number and we confirm the circuit before you pay for it.

Is it worth it

When electric heating makes sense in Dubai, and when it does not

Heating here is occasional. At Dubai airport the average January night low is about 15 °C and the average day high about 24 °C, and December and February are a degree or two warmer. Cold snaps are sharper inland: the National Centre of Meteorology reported inland and mountain areas below 10 °C in January 2026, and desert camps and farms in the early morning can fall further. The heating you need is for mornings, evenings and the coldest fortnight, not for a season.

That changes what is worth installing. A system with a high installation cost and a low running cost, such as underfloor heating in one bathroom, makes sense for a room you use every day. A system you would run for 40 evenings a year, such as a terrace heater, makes sense if the space is used as a living area. Whole-home heating mostly does not, because the air conditioner you already own can heat the room.

WhereElectric heating worth consideringWhy
Master bathroom with marble or porcelain floorUnderfloor mat, electric towel railStone feels cold underfoot, and the rooms are small, so the cost is small
Majlis, terrace, pool deck, café seatingOutdoor infrared heatersThey warm people directly and the circuit is simple
Living room with a feature wallElectric fireplaceDecorative first, a heater second
Desert home, farm, camp, mountain propertyWall or panel heaters, underfloorNights fall well below the city average
Bedrooms and living rooms in a flatUsually the air conditioner in heating modeIt delivers more heat per unit of electricity

Use the air conditioner first if it can heat

A resistance heater turns every kilowatt-hour into one kilowatt-hour of heat. A reverse-cycle air conditioner moves heat from outdoors, and its coefficient of performance is about three, so it delivers around 3 kWh of heat for each 1 kWh it uses. At the Dubai tariff of about 34 fils per kWh, 3 kWh of heat costs AED 1.02 from a 3 kW fan heater and about AED 0.34 from a heating-mode air conditioner.

Many split units sold in the Gulf are cooling-only, so check the label or remote for a heating mode before you count on it. If your unit does heat, use it for the bedroom and living room, and keep electric heating for the places the air conditioner cannot reach: the bathroom floor, the towel rail, the terrace. Our AC electrical connection page covers the circuit behind a unit.

Underfloor

Underfloor heating

Electric underfloor heating is a heating cable under the floor covering, usually arranged as a mat, with a thermostat and a floor temperature sensor. It warms the floor surface, mostly by radiating upward, and it suits a bathroom or a small room better than a large one. It is not a replacement for room heating, and in Dubai it is not meant to be.

Mat, loose cable or foil

A mat has the cable fixed to a mesh, which is quick to roll out and suits regular rooms. A loose cable is fed from a reel and fixed in a pattern, which suits awkward shapes and bathrooms with a bath, toilet and vanity in the way. A foil or film heater is thin, with a heating element between foil layers, and suits floors where almost no height can be added. A low profile helps in renovations, where the finished floor can rise very little.

In all three, the heated cable has a cold tail that runs to the thermostat, and a joint and an end seal at the far end. The cold tail, the joint and the sensor are embedded in adhesive or compound so no air gaps can overheat them.

Output and size

The usual output is 150 W per m² for a tiled floor laid over insulation. Mats are made in 100, 150 and 200 W per m², and the lower figure suits rooms where the floor is a comfort rather than a heat source. You heat only the floor you walk on: leave out the footprint of the bath, the vanity, the toilet and fixed units, because heating under fixed objects wastes power and can overheat the cable.

For a 4.5 m² bathroom floor, 150 W per m² gives 675 W, which is 2.9 A at 230 V. A 20 m² living room floor gives 3 kW, which is 13 A. We work from a measured plan of the heated area, not from the room's overall dimensions.

Insulation under the heating

Never lay the heating cable straight onto bare concrete. Heat goes down as readily as up, and without insulation under the cable, a slab or a floor above another flat takes much of the output, so the floor takes longer to warm and costs more to run. We lay an insulation board first, with the mat or cable fixed on top.

The insulation adds thickness. A typical build-up for a thin floor finish over an existing subfloor is about 24 mm, including board, cable, levelling compound and finish. We measure the available height and check door thresholds before we quote.

The floor covering must let heat through

Tile and stone conduct heat well. Thick carpet and rug underlay do not. One maker limits the combined thermal resistance of everything between the heater and the room to 0.15 m²K/W, which is a thin floor finish. Wood and vinyl have another limit: the floor surface must not exceed 27 °C for those finishes. General trade guidance caps any floor surface at 35 °C.

Rugs, bean bags and furniture that sit flat on the floor also block heat. Over time they can overheat the cable underneath them. Tell us about the furniture layout, and where a rug will live, before the heating is laid.

Do not cut, shorten or cross the cable

Heating cable is made to a set length and resistance. It must never be cut or shortened, and it must never overlap or cross itself. Makers give minimum bend radii (25 mm for one, five times the cable thickness for another), a minimum spacing between runs, and a gap from walls, around 40 mm for one maker. Surplus cable cannot be bunched under a fixture. If the mat is too big for the room, the room gets a smaller mat, and the extra is returned.

Circuit, protection and thermostat

The heating load is continuous and has no diversity, because the whole load can be on at once. We size the circuit for the full load, protect it with a 30 mA earth leakage device, and fit a local isolator. Makers limit how much heating one 30 mA device may protect: one gives 4.8 kW, and trade guidance gives 7.5 kW at 230 V. We follow the manual for the system fitted, and a Type A device is recommended.

The thermostat is usually rated for 16 A. Larger loads need a contactor or several thermostats. The floor sensor, normally a 10 kΩ type, sits between two cable runs, around 300 mm from the wall, with its wire kept clear of the heating cable. We fit a spare sensor in its own conduit, so that a failure in ten years does not mean lifting the floor.

Three stages of testing

We test the heating cable before it leaves the box, again after it is laid, and again after the floor is finished, and record each reading. A 600 W element at 230 V should read about 88 Ω, and one maker allows 5 per cent either way. Live to earth and neutral to earth should read open, with an insulation test at 500 V. The sensor should read about 8 to 12 kΩ at room temperature.

The heating stays off until the tile adhesive has cured, and one maker's minimum is 7 days. Switching on early can weaken the bond between tile and floor.

The drawing of where the heating is

We leave you an as-installed drawing showing the heated area, the cable runs, the sensor and the cold tails. Without it, the next person to drill a door stop or a towel rail bracket does not know where the cable is. A thermal camera, or a heat-sensitive sheet on the first run, shows the layout too.

Bathrooms

Towel rails, bathroom heaters and electric showers

A bathroom is where heating and water meet, and the rules are stricter here than anywhere else in the house. The UAE wiring regulations require a 30 mA earth leakage device on every final circuit in a bathroom, and a minimum of IPX4 for appliances, light fittings and accessories. They allow no ordinary socket outlets in a bathroom: the only socket allowed is a shaver outlet fed through an isolating transformer.

Keep equipment out of arm's reach of the bath and shower

The regulations do not use numbered zones. They talk about arm's reach: no equipment may be installed within arm's reach of a bath or shower, except extra-low-voltage equipment with the right IP rating. Switches must be outside the bathroom, or be cord-pull switches. In practice that places the heater, the towel rail and their controls well away from the shower, and puts the on-off control outside the door.

Electric towel rails

An electric towel rail is a heated element in a rail, usually a few hundred watts. We wire it through a fused connection unit that sits outside the bathroom or out of reach of the shower, with an IPX4 rail, a fuse sized for the rail's rating, and 30 mA earth leakage protection upstream. A dual-fuel rail, which has an electric element in a water-filled radiator, follows the same rules as a fully electric one.

Some rails come with a plug. We remove it and hardwire the rail, because a plug and socket in a bathroom is not allowed. A timer on the fused connection unit keeps the rail from running all night.

Bathroom wall heaters

A wall heater or a ceiling infrared heater in a bathroom must be IPX4 or better, mounted beyond arm's reach of the bath and shower, switched from outside the room or by a cord, and on a circuit with a 30 mA device. A 2 kW heater draws 8.7 A, so it is a circuit of its own, not a spur off the light.

Electric showers

A fixed electric shower heats water as it flows, and it draws a large current to do it. At 7.5 or 8.5 kW it needs a 40 A breaker and 6 mm² cable, and at 9.5 or 10.5 kW a 45 A breaker and 10 mm² cable. Each shower gets its own circuit from the board, a 30 mA device, and a pull-cord isolator rated at least 45 A, outside the shower area. A 6 mm² cable covers up to 8.5 kW on a clipped run under about 18 m, and a longer run, or one buried in insulation, needs a thicker cable.

Many showers made for the UK are rated for 240 V. At 230 V the heating power falls with the square of the voltage, so a 10.5 kW shower gives about 9.6 kW, and a 7.5 kW one about 6.9 kW. That is why the water temperature of a shower bought abroad can disappoint.

An electric shower also needs the water side to suit it. The mains-pressure models need at least 1 bar of pressure at 8 litres a minute for the lower wattages, and 1.5 bar at 11 litres a minute for 10.5 kW, so they may not work on a low-pressure tank feed. Colder inlet water makes the element work harder, and the flow falls. The plumbing is a plumber's job, and we wire the circuit. If you want hot water from a tank for a whole bathroom, see our water heater installation service.

Fireplaces and heaters

Fireplaces, wall heaters and patio heaters

Electric fireplaces

An electric fireplace is a flame effect with a heater, in a freestanding unit, a wall-mounted unit, or an insert built into a recess. The flame effect draws little power. The heater draws the load, and in many models it is 1.5 to 2 kW. A 2 kW heater is 8.7 A at 230 V, so it can run from a 13 A plug on its own circuit, though a built-in unit is better hardwired.

For a recessed or built-in unit, the wiring is done before the wall is closed: a back box or a power point behind the unit, an outlet that is not pinched behind it, and a cable route that stays clear of the heat. Makers publish minimum clearances to a mantel, a television and anything combustible, and they vary by model and by side. A TV above the fireplace is possible only if both manuals allow it and the heat outlet is not blocked. We read the manual before the joiner frames the opening, since moving a power point after the wall is finished costs more than placing it correctly.

Do not run a fireplace from an extension lead or a power strip unless the maker allows it, and do not stand furniture against the air intake or outlet.

If an existing gas fire is being replaced with an electric one, the gas should be disconnected and capped by a qualified gas contractor first. We do the electrical side once the gas side is signed off.

Wall and panel heaters

A fixed wall or panel heater is a heater with a thermostat, usually 1 to 2 kW, connected to the circuit through a fused connection unit with a switch. We put it where the cold is: under a window, in a hall, or in a room without an air conditioner. It is not a good fit for a whole house. A 2 kW heater running for ten hours uses 20 kWh, which is about AED 6.80 at 34 fils.

Outdoor infrared heaters

An infrared heater warms people and surfaces directly, not the air, so it works on a windy terrace where a fan heater would not. A wall- or ceiling-mounted unit of 2 to 3 kW suits a majlis, a pool deck, a balcony or café seating. A 3 kW heater draws 13 A, so each one gets its own circuit, and makers recommend a separate circuit because a high-wattage heater on a shared circuit overloads it.

Outdoor heaters are normally rated between IP44 and IP65, so they can stay out all year without a cover. The plug and socket, if the heater has one, must be weatherproof too. We prefer a hardwired connection from a weatherproof isolator, because a plug outdoors is an extra part to fail in dust and humidity. We follow the maker's minimum mounting height and the clearance to roofs, awnings and trees, because the heat is intense at close range.

The more exposed the position, the more heat is lost. More heaters, higher power or a screen on the windward side keep the space usable. Several heaters on one terrace are spread across the phases of a three-phase supply where there is one, so one phase does not carry them all. Our three-phase and load upgrade service covers the supply behind that.

Circuits and control

Circuits, thermostats and smart control

Heating loads are different from lighting and sockets in one way: they run at full load for hours. A 3 kW heater on for four hours draws 13 A throughout, not for a second. We size cables and breakers with that in mind and allow for the temperature of the place the cable runs.

Typical circuits

HeaterTypical loadCurrent at 230 VCircuit
Towel railA few hundred watts1 to 3 AFused connection unit, fuse sized to the rail
Underfloor heating, 4.5 m² bathroom675 W2.9 AOwn protected circuit or spur, thermostat, 30 mA device
Underfloor heating, 20 m² room3 kW13 AOwn circuit, 16 A breaker, 2.5 mm² cable
Wall or panel heater1 to 2 kW4.3 to 8.7 AFused connection unit, own circuit for 2 kW
Electric fireplace1.5 to 2 kW6.5 to 8.7 AOwn circuit, plug or hardwired
Outdoor infrared heater2 to 3 kW8.7 to 13 AOwn weatherproof circuit, 16 A breaker
Electric shower7.5 to 10.5 kW31 to 46 AOwn circuit, 40 A or 45 A breaker, 6 mm² or 10 mm² cable

The nameplate or the maker's manual overrides the table. Where the cable runs through a hot roof void, we step up the cable size, because 2.5 mm² cable carries about 27 A at 30 °C and roughly 21 A at 45 °C. Our AC electrical connection page explains the same derating for air conditioner circuits. If the board has no spare way, or the total load is too much for the main breaker, the first job is a DB box and distribution board upgrade.

Thermostats, timers and smart control

Underfloor heating needs a thermostat that reads a floor sensor, an air sensor or both. Most thermostats are rated for 16 A, which is plenty for a bathroom floor and not enough for a large living room. A timer on a towel rail or a terrace heater stops it from running unattended. A Wi-Fi thermostat lets you switch the floor on from the car, and the heating season is short enough that a manual timer is a fine alternative.

Heating automation and smart thermostats are covered in our smart thermostat installation service. For a heater you already own, we check that the thermostat's rating matches the load before we connect it.

Cost and running cost

What electric heating costs to install and to run in Dubai

Underfloor heating for one bathroom floor, up to about 5 m², usually costs AED 1,940 to 3,880 for the mat, sensor, thermostat, circuit and labour, not counting the tiling. A towel rail or a wall heater on its own circuit is AED 195 to 485. The site visit costs AED 50, and the quote follows it.

JobTypical price (AED)
Underfloor heating, bathroom up to 5 m², excluding tiling2,000 to 4,000
Underfloor heating, larger roomQuote after a site visit
Electric towel rail, hardwired through a fused connection unit250 to 500
Wall or panel heater, fused connection unit200 to 400
Electric fireplace, back box and connection300 to 700
Outdoor infrared heater, own circuit, up to 10 m from the board600 to 1,200
Electric shower: circuit, isolator and connection700 to 1,500

What moves the price

For underfloor heating the main variables are the heated area, the insulation board and levelling compound, and whether the floor is being laid new or lifted. A new bathroom, where the heating goes in before the tiles, is cheaper than a retrofit. For heaters, it is the distance from the board, whether the wall must be chased, and the board's spare capacity. If the board has no spare way, our DB box and distribution board service covers the upgrade first.

What it costs to run

The cost of any heater is its power in kilowatts, times the hours it runs, times the tariff. Dubai's residential tariff is 23 fils per kWh for the first 2,000 kWh in a month, 28 fils for the next 2,000 and higher beyond that, plus a fuel surcharge of about 6 fils and 5 per cent VAT. A home that already runs air conditioners is usually in the second slab, which makes 34 fils the working figure. In the first slab it is 29 fils.

HeaterHow it is usedEnergy a dayCost a dayA 90-day winter
Underfloor heating, 4.5 m² (675 W)3 hours2.0 kWhAED 0.69AED 62
Underfloor heating, 20 m² (3 kW)3 hours9 kWhAED 3.06AED 275
Towel rail, 300 W2 hours0.6 kWhAED 0.20AED 18
Electric fireplace, 2 kW3 hours6 kWhAED 2.04AED 184
Outdoor infrared heater, 3 kW4 hours12 kWhAED 4.08AED 367

Those are small numbers because the season is short, which is the point of choosing heaters for places and not for the whole house. The expensive way to heat in Dubai is a resistance heater in a large room for long hours. The cheap ways are heat in the room you stand in, a floor you turn on for the morning, and an air conditioner with a heating mode.

Step by step

How an underfloor heating installation runs, step by step

  1. 1
    Survey and plan. We measure the heated area, check the available floor height, the board and the route from the thermostat to the heating, and agree where the sensor goes.
  2. 2
    Choose the system. We pick the output (usually 150 W per m²) and the mat or cable to suit the room and the floor finish.
  3. 3
    Prepare the floor. The subfloor is cleaned and levelled, insulation board goes down, and a conduit is set for the sensor and the cold tails.
  4. 4
    Test the element. Before it leaves the box, we read its resistance and record it against the maker's figure.
  5. 5
    Lay the heating. The mat or cable goes down without cuts, crossings or tight bends, clear of walls and fixed units. The sensor is placed between two runs. We test again and record it.
  6. 6
    Floor finish. The tiler lays the finish. We recheck the element during the work where the tiler allows it, and again once the floor is finished.
  7. 7
    Cure. The heating stays off until the adhesive has cured, 7 days at minimum for one maker.
  8. 8
    Connect and test. The thermostat, the isolator and the circuit are connected. We insulation-test at 500 V and trip-test the earth leakage device.
  9. 9
    Commission. We switch on, check the floor warms evenly, and use a thermal camera or a heat-sensitive sheet where the layout is complicated.
  10. 10
    Handover. You get the as-installed drawing, the test sheet and the thermostat settings.

For a towel rail, a wall heater, a fireplace or an outdoor heater, the job is shorter: confirm the circuit, fit the connection unit or isolator, connect the heater, and test. Most are a half-day visit.

Faults

Electric heating problems and repairs

Stop and switch off at the isolator if you smell burning from a heater, find a hot spot on a floor, or feel a tingle from a towel rail or a heater casing. Switching on again to see whether the problem comes back can make an overheating connection worse.

The floor does not warm up

The usual causes are a thermostat set too low, a floor sensor fault, a tripped earth leakage device, or a cable fault. We read the sensor, which should show about 8 to 12 kΩ at room temperature, and the element's resistance against its recorded value. A thermostat error code often means the sensor. If a spare sensor was fitted, we switch to it, and the floor does not need lifting.

The earth leakage device trips when the floor switches on

The insulation has been damaged, or moisture has got in. The heating cable can be nicked by a trowel, a drill or a nail, or a tile cutter, and the fault may not show until the floor is switched on. We test live to earth at 500 V. A reading that is not open confirms damage, and we find the position with resistance measurements or a thermal camera.

Cold spots or hot spots

A strip of cold floor means a gap in the cable spacing or an air gap in the insulation. A hot spot means heat is being trapped: a rug, a heavy piece of furniture, an unheated area under a fixed unit, or cable that has been laid too close together. The remedy depends on the cause. Moving a rug is free, and relaying cable means lifting the floor.

A cable that has broken

We locate the break with resistance readings and a thermal camera, so the repair opens as little floor as possible. If the maker allows a repair joint, we fit one and record its position on the drawing. If it does not, the section is replaced.

As a rule, if a repair touches the heating cable, we update the as-installed drawing and retest at 500 V before the floor is switched on again.

A towel rail or fireplace that does not heat

A towel rail that stays cold is usually a switch, fuse or timer on the fused connection unit, or a failed element. A rail that trips the earth leakage device may have water inside. A fireplace that shows flame but no heat has usually shut its heater off on an overheat cut-out, often because an air inlet or outlet is blocked. If the cut-out resets and trips again, the element or a fan has failed.

An outdoor heater that trips the breaker

Likely causes are a breaker too small for a 3 kW heater, water in the plug or the connection, a failed lamp, or several heaters on one circuit. We check the circuit rating against the heater, test insulation, and move any shared heaters onto their own circuits.

Why us and how to book

Electric heating installation with Circuit Dubai

  • The load is sized before the heater is bought. Send the model number and we confirm the circuit.
  • Records at each stage. Resistance and insulation readings are written down for every underfloor system we fit.
  • Wet areas done to the regulations. Equipment outside arm's reach, controls outside the room, 30 mA protection on every circuit.
  • One team for the board and the heater.
  • A drawing of where the heating is. So the next job on that floor does not cut through it.

We work across all of Dubai. Our office is in Al Quoz.

If you are also planning a water heater, an AC electrical connection, smart thermostat installation, a three-phase upgrade or solar panels, we can scope them at the same visit and save a second call-out.

Our office: Office 1271, Oasis Mall, Al Quoz 1, Dubai, UAE
Phone: +971 55 407 7427
FAQs

Electric heating questions we hear from Dubai homeowners

Is underfloor heating worth it in Dubai?

For a bathroom or a small room you use every morning in winter, yes. A 4.5 m² floor costs about AED 0.70 a day to run for 3 hours, and about AED 60 for a whole winter. For a large living room it is not worth running for long hours, and the air conditioner in heating mode is cheaper.

How much does it cost to run?

Multiply the heater's kilowatts by the hours and by about AED 0.34. A 675 W bathroom floor for three hours is 2 kWh, or AED 0.69. A 3 kW outdoor heater for four hours is 12 kWh, or AED 4.08.

Can underfloor heating go under marble or porcelain?

Yes. Tile and stone conduct heat well and are the usual finish. Wood and vinyl are limited to a surface temperature of 27 °C, and thick carpet or rug underlay holds heat in and is not suitable.

Can it go under an existing floor?

Not under tiles that stay in place. The heating sits between the subfloor and the finish, so the finish is lifted or replaced. Some systems are made for floating floors, and the maker's manual says which.

How long does installation take?

A bathroom floor takes about a day for the heating, with the tiler's time on top. The heating then stays off until the adhesive has cured, 7 days at minimum for one maker.

Can I plug an electric towel rail into a socket?

No. A bathroom has no ordinary sockets under the UAE wiring regulations. The rail is hardwired through a fused connection unit outside the bathroom.

Can I use a heater or shower made for 240 V?

Yes, but it gives less heat. Heating power falls with the square of the voltage, so a 240 V element on 230 V gives about 8 per cent less. A 10.5 kW shower gives about 9.6 kW.

Does an electric fireplace need its own circuit?

A 2 kW heater draws 8.7 A, so we give it its own circuit unless the manual allows otherwise. The flame effect alone draws very little.

Is it safe to use outdoor heaters in Dubai's humidity?

Yes, if the heater is rated IP44 to IP65, on its own circuit, with 30 mA protection and a weatherproof isolator. We hardwire where we can, because plugs outdoors are the weak point.

Can I put a TV above an electric fireplace?

Sometimes. The heat outlet must stay clear, and both the fireplace's manual and the TV's manual must allow it. We read both before the wall is framed.

Do you install gas heaters?

Yes. We fit gas heaters as well as electric ones.

Do you supply the heaters as well?

Yes, or we fit the one you have bought. If you have bought one, send us the model number first and we confirm the circuit.

Ready for heating that is wired properly?

Send the room size, the floor type, a photo of your distribution board, and the heater model if you have chosen one. We reply instantly on chat with a price and a time, so you know what the job involves before anyone arrives.